Study shows that Baylis RF Needle Improves Safety and Efficacy of Transseptal Puncture
TOP Medical is share the results of the study of Dr. Winkle published in Hearth Rhythm.
The use of a radiofrequency (RF) needle improves the speed, efficacy, and safety of trans-septal catheterization in patients undergoing ablation of the left atrium for atrial fibrillation (AF). These are the findings from a single-center
study published in Heart Rhythm. “The introduction of the RF trans-septal needle represents the first major equipment advance for trans-septal puncture in almost 50 years,” write the investigators. “We had done a large number of trans-septal punctures using standard needles,” says Dr Roger Winkle, who led the study. “It was always an uncomfortable procedure and we were on the look-out for better and safer tools.” The NRG® RF trans-septal needle was developed by Baylis Medical (Saint‑Laurent, Canada) and was used by the investigators for a series of 575 AF ablations. The outcomes of these procedures were compared with the researchers’ previous experience of using standard BRK™ trans-septal needles (St Jude Medical, Maple Grove, USA) for 975 ablation procedures.
Among the 1,167 patients who underwent AF ablation with either of the two needles, the most prevalent rhythm abnormality was persistent AF (52.9%). The NRG® needle had a significantly lower failure rate for transseptal puncture than the standard needle (0.17% vs 1.23%, P = 0.039). The only case in which the RF needle failed to perforate the septum was in a patient with hypertrophic cardiomyopathy. None of the patients undergoing ablation with the RF needle experienced pericardial tamponade, compared with nine of those whose procedure involved the use of the standard needle (P = 0.031).
“We hope our work will stimulate others to adopt the new RF technology,” concludes Dr Winkle. “It should reduce complications from AF ablation and other procedures that require left atrial entry.”
Original article Winkle, R. A., Mead, R. H., Engel, G. & Patrawala, R. A. The use of a radiofrequency needle improves the safety and efficacy of trans-septal puncture
for atrial fibrillation ablation. Heart Rhythm doi:10.1016/
j.hrthm.2011.04.032
- Covidien acquires OneShot Ablation System of Maya Medical
- Butterfly Foundation in Nepal opens Health Clinic supported by TOP Medical
- UMC Utrecht to start Study with Cre8 Polymer-free Drug Eluting Stent
- Cre8 Polymer Free, the Effective DES Solution with No Safety Concerns
- Boston Scientific to Acquire Cameron Health
- TOP Medical to expand its business in brand new facility
- TOP Medical receives award for Outstanding Performances in 2011
- TOP Medical to attend Complex PCI, Left Main and CTO Summit in New York
- TOP Medical to Launch the Cre8 Polymerfree Drug Eluting Stent
- TOP Medical to sell Kimberly-Clark Pain Management Product Line
- Cameron Health announced 1,000th S-ICD Implant
- Study shows that Baylis RF Needle Improves Safety and Efficacy of Transseptal Puncture
- TOP Medical launches the ASAHI SION, a New Generation Workhorse Wire with a 3D Torque Revolution
- TOP Medical expands business with new Neuro Therapies Division
- TOP Medical signs exclusive agreement with Toray International to distribute the Inoue-Balloon
- Tryton Announces CE Mark for Larger-Diameter Sizes of Side Branch Stent.
- TOP Medical Finished in New York City Marathon